Review



tissue-level implants straumann® standard plus – slactive  (Straumann GmbH)

 
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    Straumann GmbH tissue-level implants straumann® standard plus – slactive
    Tissue Level Implants Straumann® Standard Plus – Slactive, supplied by Straumann GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/standard+plus+slactive+(straumann)/straumann+tissue+level+implants/pmc11402838-25-5-8
    Average 90 stars, based on 1 article reviews
    tissue-level implants straumann® standard plus – slactive - by Bioz Stars, 2026-09
    90/100 stars

    Images

    Related Articles

    Clinical Proteomics:

    Article Title: Immediate implant placement and simultaneous bone grafting with bone cement in extraction sockets: A systematic review
    Article Snippet: Implant dimension , 3.3-mm-diameter, 12-mm-long ITI titanium plasma-sprayed Straumann implants , 3-mm-diameter, 10-mm-long B-type cylindrical titanium alloy shape implants , Parallel-wall, screw-type, 3.25-mm-diameter, 11.5- or 13-mm-long titanium implants , Parallel-wall, screw-type, 3.25-mm-diameter, 11.5- or 13-mm-long titanium implants , Standard plus 4.1-mm-diameter, 8-mm-long SLActive (Straumann USA).

    Article Title: Mandibular overdentures retained by 1 or 2 implants: a 5-year randomized clinical trial on implant stability and peri-implant outcomes
    Article Snippet: All participants received 4.1 mm diameter tissue-level implants (Straumann ® Standard Plus – SLActive ® , Institut Straumann AG, Basel, Switzerland), installed according to the manufacturer’s recommendations, using a flapped surgery and early loading protocol.

    Article Title: Evaluation of short dental implant in posterior atrophic partially edentulous maxilla and mandible .
    Article Snippet: Straumann Standard Plus SLActive surface short implant that used in this study characterized by unique implant design where implant body itself has a solid screw parallel-wall configuration, with the thread pitch of 0.8 mm and made of Roxolid (Titanium-Zirconium alloy) with rounded apex, the body has 4.1 mm, and the neck has 4.8mm (for the RN design), the “tulip-shaped” design helps to improve the primary stability at the neck of the implant, especially in the posterior maxilla sites .The polished collar neck provides a crown-toimplant connection at a supra-gingival (Soft Tissue) level, allowing for less crestal bone loss and an excellent peri-implant tissue stability.

    Article Title: Long-term clinical performance of short 6-mm implants supporting single crowns in the posterior region: A 10-year cohort study.
    Article Snippet: School of Dentistry, Pontifical Catholic University of Rio Grande do Sul, Porto Alegre, Brazil Private Practice, Porto Alegre, Brazil Private Practice, Jaú, Brazil School of Dentistry, Federal University of Santa Catarina, Florian opolis, Brazil Postgraduate Program in Epidemiology, Federal University of Rio Grande do Sul, Porto Alegre, Brazil School of Dentistry, University of São Paulo, São Paulo, Brazil

    Article Title: Mandibular overdentures retained by 1 or 2 implants: a 5-year randomized clinical trial on implant stability and peri-implant outcomes
    Article Snippet: All participants received 4.1 mm diameter tissue-level implants (Straumann ® Standard Plus – SLActive ® , Institut Straumann AG), installed in the mandible midline (1-IOD; n = 23) or the lateral incisor-canine area bilaterally (2-IOD; n = 24), and loaded after 3 weeks.

    Article Title: Oral rehabilitation and associated quality of life following mandibular reconstruction with free fibula flap: a cross-sectional study
    Article Snippet: Further, the time interval for endosseous implant placement [Straumann SLActive standard or standard plus implants (Straumann GmbH; Freiburg, Germany) or Xive implants (Dentsply Sirona Deutschland GmbH; Bensheim, Germany)], and the duration until consecutive prosthetic restoration were recorded.

    Article Title: Narrow Versus Standard Diameter Implants for Supporting Single Crown Restorations in the Posterior Jaw: A Randomised Controlled Trial
    Article Snippet: Fig. 2 Clinical images of a patient in the standard diameter implant group: (A) surgical guide in situ. (B) osteotomy site with 2.2 mm guiding pin. (C) periapical radiograph of 2.8 mm guiding pin. (D) Straumann Standard Plus Roxolid SLActive RN 4.1 × 10 mm. (E) Dental implant in situ. (F) flap closure with 4-0 PGA resorbable suture. (G) Periapical radiograph immediately after dental implant placement. (H) 3-month post-operative periapical radiograph following placement of healing abutment. (I, J) Delivery of screw-retained implant-supported crown. (K) Peri-apical radiograph immediately after delivery of screw-retained implant-supported crown.

    Article Title: 3D virtual patient-Magnetically retained printed stackable system for implant guided placement: Case report.
    Article Snippet: Correspondence Camila Sales Jreige, Department of Prosthodontics, University of São Paulo School of Dentistry, 2227 Professor Lineu Prestes Avenue, São Paulo, SP, Brazil Email: camilajreige@usp.br Abstract Objective: The aim of this report is to present the complete workflow of 3D virtual patient for planning and performing implant surgery with magnetically retained 3Dprinted stackable guides.. Clinical Considerations: A 3D-printed stackable system was proposed based on bone, dental, and facial references.. Initially, a 66-year-old male patient was digitalized through photographs, cone beam computed tomography, and intraoral scans (Virtuo Vivo, Straumann).

    Extraction:

    Article Title: Immediate implant placement and simultaneous bone grafting with bone cement in extraction sockets: A systematic review
    Article Snippet: Implant dimension , 3.3-mm-diameter, 12-mm-long ITI titanium plasma-sprayed Straumann implants , 3-mm-diameter, 10-mm-long B-type cylindrical titanium alloy shape implants , Parallel-wall, screw-type, 3.25-mm-diameter, 11.5- or 13-mm-long titanium implants , Parallel-wall, screw-type, 3.25-mm-diameter, 11.5- or 13-mm-long titanium implants , Standard plus 4.1-mm-diameter, 8-mm-long SLActive (Straumann USA).

    Article Title: Mandibular overdentures retained by 1 or 2 implants: a 5-year randomized clinical trial on implant stability and peri-implant outcomes
    Article Snippet: All participants received 4.1 mm diameter tissue-level implants (Straumann ® Standard Plus – SLActive ® , Institut Straumann AG, Basel, Switzerland), installed according to the manufacturer’s recommendations, using a flapped surgery and early loading protocol.

    Article Title: Evaluation of short dental implant in posterior atrophic partially edentulous maxilla and mandible .
    Article Snippet: Straumann Standard Plus SLActive surface short implant that used in this study characterized by unique implant design where implant body itself has a solid screw parallel-wall configuration, with the thread pitch of 0.8 mm and made of Roxolid (Titanium-Zirconium alloy) with rounded apex, the body has 4.1 mm, and the neck has 4.8mm (for the RN design), the “tulip-shaped” design helps to improve the primary stability at the neck of the implant, especially in the posterior maxilla sites .The polished collar neck provides a crown-toimplant connection at a supra-gingival (Soft Tissue) level, allowing for less crestal bone loss and an excellent peri-implant tissue stability.

    Article Title: Long-term clinical performance of short 6-mm implants supporting single crowns in the posterior region: A 10-year cohort study.
    Article Snippet: School of Dentistry, Pontifical Catholic University of Rio Grande do Sul, Porto Alegre, Brazil Private Practice, Porto Alegre, Brazil Private Practice, Jaú, Brazil School of Dentistry, Federal University of Santa Catarina, Florian opolis, Brazil Postgraduate Program in Epidemiology, Federal University of Rio Grande do Sul, Porto Alegre, Brazil School of Dentistry, University of São Paulo, São Paulo, Brazil

    Article Title: Mandibular overdentures retained by 1 or 2 implants: a 5-year randomized clinical trial on implant stability and peri-implant outcomes
    Article Snippet: All participants received 4.1 mm diameter tissue-level implants (Straumann ® Standard Plus – SLActive ® , Institut Straumann AG), installed in the mandible midline (1-IOD; n = 23) or the lateral incisor-canine area bilaterally (2-IOD; n = 24), and loaded after 3 weeks.

    Article Title: Oral rehabilitation and associated quality of life following mandibular reconstruction with free fibula flap: a cross-sectional study
    Article Snippet: Further, the time interval for endosseous implant placement [Straumann SLActive standard or standard plus implants (Straumann GmbH; Freiburg, Germany) or Xive implants (Dentsply Sirona Deutschland GmbH; Bensheim, Germany)], and the duration until consecutive prosthetic restoration were recorded.

    Article Title: Narrow Versus Standard Diameter Implants for Supporting Single Crown Restorations in the Posterior Jaw: A Randomised Controlled Trial
    Article Snippet: Fig. 2 Clinical images of a patient in the standard diameter implant group: (A) surgical guide in situ. (B) osteotomy site with 2.2 mm guiding pin. (C) periapical radiograph of 2.8 mm guiding pin. (D) Straumann Standard Plus Roxolid SLActive RN 4.1 × 10 mm. (E) Dental implant in situ. (F) flap closure with 4-0 PGA resorbable suture. (G) Periapical radiograph immediately after dental implant placement. (H) 3-month post-operative periapical radiograph following placement of healing abutment. (I, J) Delivery of screw-retained implant-supported crown. (K) Peri-apical radiograph immediately after delivery of screw-retained implant-supported crown.

    Article Title: 3D virtual patient-Magnetically retained printed stackable system for implant guided placement: Case report.
    Article Snippet: Correspondence Camila Sales Jreige, Department of Prosthodontics, University of São Paulo School of Dentistry, 2227 Professor Lineu Prestes Avenue, São Paulo, SP, Brazil Email: camilajreige@usp.br Abstract Objective: The aim of this report is to present the complete workflow of 3D virtual patient for planning and performing implant surgery with magnetically retained 3Dprinted stackable guides.. Clinical Considerations: A 3D-printed stackable system was proposed based on bone, dental, and facial references.. Initially, a 66-year-old male patient was digitalized through photographs, cone beam computed tomography, and intraoral scans (Virtuo Vivo, Straumann).

    Micro-CT:

    Article Title: Immediate implant placement and simultaneous bone grafting with bone cement in extraction sockets: A systematic review
    Article Snippet: Implant dimension , 3.3-mm-diameter, 12-mm-long ITI titanium plasma-sprayed Straumann implants , 3-mm-diameter, 10-mm-long B-type cylindrical titanium alloy shape implants , Parallel-wall, screw-type, 3.25-mm-diameter, 11.5- or 13-mm-long titanium implants , Parallel-wall, screw-type, 3.25-mm-diameter, 11.5- or 13-mm-long titanium implants , Standard plus 4.1-mm-diameter, 8-mm-long SLActive (Straumann USA).

    Article Title: Mandibular overdentures retained by 1 or 2 implants: a 5-year randomized clinical trial on implant stability and peri-implant outcomes
    Article Snippet: All participants received 4.1 mm diameter tissue-level implants (Straumann ® Standard Plus – SLActive ® , Institut Straumann AG, Basel, Switzerland), installed according to the manufacturer’s recommendations, using a flapped surgery and early loading protocol.

    Article Title: Evaluation of short dental implant in posterior atrophic partially edentulous maxilla and mandible .
    Article Snippet: Straumann Standard Plus SLActive surface short implant that used in this study characterized by unique implant design where implant body itself has a solid screw parallel-wall configuration, with the thread pitch of 0.8 mm and made of Roxolid (Titanium-Zirconium alloy) with rounded apex, the body has 4.1 mm, and the neck has 4.8mm (for the RN design), the “tulip-shaped” design helps to improve the primary stability at the neck of the implant, especially in the posterior maxilla sites .The polished collar neck provides a crown-toimplant connection at a supra-gingival (Soft Tissue) level, allowing for less crestal bone loss and an excellent peri-implant tissue stability.

    Article Title: Long-term clinical performance of short 6-mm implants supporting single crowns in the posterior region: A 10-year cohort study.
    Article Snippet: School of Dentistry, Pontifical Catholic University of Rio Grande do Sul, Porto Alegre, Brazil Private Practice, Porto Alegre, Brazil Private Practice, Jaú, Brazil School of Dentistry, Federal University of Santa Catarina, Florian opolis, Brazil Postgraduate Program in Epidemiology, Federal University of Rio Grande do Sul, Porto Alegre, Brazil School of Dentistry, University of São Paulo, São Paulo, Brazil

    Article Title: Mandibular overdentures retained by 1 or 2 implants: a 5-year randomized clinical trial on implant stability and peri-implant outcomes
    Article Snippet: All participants received 4.1 mm diameter tissue-level implants (Straumann ® Standard Plus – SLActive ® , Institut Straumann AG), installed in the mandible midline (1-IOD; n = 23) or the lateral incisor-canine area bilaterally (2-IOD; n = 24), and loaded after 3 weeks.

    Article Title: Oral rehabilitation and associated quality of life following mandibular reconstruction with free fibula flap: a cross-sectional study
    Article Snippet: Further, the time interval for endosseous implant placement [Straumann SLActive standard or standard plus implants (Straumann GmbH; Freiburg, Germany) or Xive implants (Dentsply Sirona Deutschland GmbH; Bensheim, Germany)], and the duration until consecutive prosthetic restoration were recorded.

    Article Title: Narrow Versus Standard Diameter Implants for Supporting Single Crown Restorations in the Posterior Jaw: A Randomised Controlled Trial
    Article Snippet: Fig. 2 Clinical images of a patient in the standard diameter implant group: (A) surgical guide in situ. (B) osteotomy site with 2.2 mm guiding pin. (C) periapical radiograph of 2.8 mm guiding pin. (D) Straumann Standard Plus Roxolid SLActive RN 4.1 × 10 mm. (E) Dental implant in situ. (F) flap closure with 4-0 PGA resorbable suture. (G) Periapical radiograph immediately after dental implant placement. (H) 3-month post-operative periapical radiograph following placement of healing abutment. (I, J) Delivery of screw-retained implant-supported crown. (K) Peri-apical radiograph immediately after delivery of screw-retained implant-supported crown.

    Article Title: 3D virtual patient-Magnetically retained printed stackable system for implant guided placement: Case report.
    Article Snippet: Correspondence Camila Sales Jreige, Department of Prosthodontics, University of São Paulo School of Dentistry, 2227 Professor Lineu Prestes Avenue, São Paulo, SP, Brazil Email: camilajreige@usp.br Abstract Objective: The aim of this report is to present the complete workflow of 3D virtual patient for planning and performing implant surgery with magnetically retained 3Dprinted stackable guides.. Clinical Considerations: A 3D-printed stackable system was proposed based on bone, dental, and facial references.. Initially, a 66-year-old male patient was digitalized through photographs, cone beam computed tomography, and intraoral scans (Virtuo Vivo, Straumann).

    Control:

    Article Title: Immediate implant placement and simultaneous bone grafting with bone cement in extraction sockets: A systematic review
    Article Snippet: Implant dimension , 3.3-mm-diameter, 12-mm-long ITI titanium plasma-sprayed Straumann implants , 3-mm-diameter, 10-mm-long B-type cylindrical titanium alloy shape implants , Parallel-wall, screw-type, 3.25-mm-diameter, 11.5- or 13-mm-long titanium implants , Parallel-wall, screw-type, 3.25-mm-diameter, 11.5- or 13-mm-long titanium implants , Standard plus 4.1-mm-diameter, 8-mm-long SLActive (Straumann USA).

    Article Title: Mandibular overdentures retained by 1 or 2 implants: a 5-year randomized clinical trial on implant stability and peri-implant outcomes
    Article Snippet: All participants received 4.1 mm diameter tissue-level implants (Straumann ® Standard Plus – SLActive ® , Institut Straumann AG, Basel, Switzerland), installed according to the manufacturer’s recommendations, using a flapped surgery and early loading protocol.

    Article Title: Evaluation of short dental implant in posterior atrophic partially edentulous maxilla and mandible .
    Article Snippet: Straumann Standard Plus SLActive surface short implant that used in this study characterized by unique implant design where implant body itself has a solid screw parallel-wall configuration, with the thread pitch of 0.8 mm and made of Roxolid (Titanium-Zirconium alloy) with rounded apex, the body has 4.1 mm, and the neck has 4.8mm (for the RN design), the “tulip-shaped” design helps to improve the primary stability at the neck of the implant, especially in the posterior maxilla sites .The polished collar neck provides a crown-toimplant connection at a supra-gingival (Soft Tissue) level, allowing for less crestal bone loss and an excellent peri-implant tissue stability.

    Article Title: Long-term clinical performance of short 6-mm implants supporting single crowns in the posterior region: A 10-year cohort study.
    Article Snippet: School of Dentistry, Pontifical Catholic University of Rio Grande do Sul, Porto Alegre, Brazil Private Practice, Porto Alegre, Brazil Private Practice, Jaú, Brazil School of Dentistry, Federal University of Santa Catarina, Florian opolis, Brazil Postgraduate Program in Epidemiology, Federal University of Rio Grande do Sul, Porto Alegre, Brazil School of Dentistry, University of São Paulo, São Paulo, Brazil

    Article Title: Mandibular overdentures retained by 1 or 2 implants: a 5-year randomized clinical trial on implant stability and peri-implant outcomes
    Article Snippet: All participants received 4.1 mm diameter tissue-level implants (Straumann ® Standard Plus – SLActive ® , Institut Straumann AG), installed in the mandible midline (1-IOD; n = 23) or the lateral incisor-canine area bilaterally (2-IOD; n = 24), and loaded after 3 weeks.

    Article Title: Oral rehabilitation and associated quality of life following mandibular reconstruction with free fibula flap: a cross-sectional study
    Article Snippet: Further, the time interval for endosseous implant placement [Straumann SLActive standard or standard plus implants (Straumann GmbH; Freiburg, Germany) or Xive implants (Dentsply Sirona Deutschland GmbH; Bensheim, Germany)], and the duration until consecutive prosthetic restoration were recorded.

    Article Title: Narrow Versus Standard Diameter Implants for Supporting Single Crown Restorations in the Posterior Jaw: A Randomised Controlled Trial
    Article Snippet: Fig. 2 Clinical images of a patient in the standard diameter implant group: (A) surgical guide in situ. (B) osteotomy site with 2.2 mm guiding pin. (C) periapical radiograph of 2.8 mm guiding pin. (D) Straumann Standard Plus Roxolid SLActive RN 4.1 × 10 mm. (E) Dental implant in situ. (F) flap closure with 4-0 PGA resorbable suture. (G) Periapical radiograph immediately after dental implant placement. (H) 3-month post-operative periapical radiograph following placement of healing abutment. (I, J) Delivery of screw-retained implant-supported crown. (K) Peri-apical radiograph immediately after delivery of screw-retained implant-supported crown.

    Article Title: 3D virtual patient-Magnetically retained printed stackable system for implant guided placement: Case report.
    Article Snippet: Correspondence Camila Sales Jreige, Department of Prosthodontics, University of São Paulo School of Dentistry, 2227 Professor Lineu Prestes Avenue, São Paulo, SP, Brazil Email: camilajreige@usp.br Abstract Objective: The aim of this report is to present the complete workflow of 3D virtual patient for planning and performing implant surgery with magnetically retained 3Dprinted stackable guides.. Clinical Considerations: A 3D-printed stackable system was proposed based on bone, dental, and facial references.. Initially, a 66-year-old male patient was digitalized through photographs, cone beam computed tomography, and intraoral scans (Virtuo Vivo, Straumann).

    Comparison:

    Article Title: Immediate implant placement and simultaneous bone grafting with bone cement in extraction sockets: A systematic review
    Article Snippet: Implant dimension , 3.3-mm-diameter, 12-mm-long ITI titanium plasma-sprayed Straumann implants , 3-mm-diameter, 10-mm-long B-type cylindrical titanium alloy shape implants , Parallel-wall, screw-type, 3.25-mm-diameter, 11.5- or 13-mm-long titanium implants , Parallel-wall, screw-type, 3.25-mm-diameter, 11.5- or 13-mm-long titanium implants , Standard plus 4.1-mm-diameter, 8-mm-long SLActive (Straumann USA).

    Article Title: Mandibular overdentures retained by 1 or 2 implants: a 5-year randomized clinical trial on implant stability and peri-implant outcomes
    Article Snippet: All participants received 4.1 mm diameter tissue-level implants (Straumann ® Standard Plus – SLActive ® , Institut Straumann AG, Basel, Switzerland), installed according to the manufacturer’s recommendations, using a flapped surgery and early loading protocol.

    Article Title: Evaluation of short dental implant in posterior atrophic partially edentulous maxilla and mandible .
    Article Snippet: Straumann Standard Plus SLActive surface short implant that used in this study characterized by unique implant design where implant body itself has a solid screw parallel-wall configuration, with the thread pitch of 0.8 mm and made of Roxolid (Titanium-Zirconium alloy) with rounded apex, the body has 4.1 mm, and the neck has 4.8mm (for the RN design), the “tulip-shaped” design helps to improve the primary stability at the neck of the implant, especially in the posterior maxilla sites .The polished collar neck provides a crown-toimplant connection at a supra-gingival (Soft Tissue) level, allowing for less crestal bone loss and an excellent peri-implant tissue stability.

    Article Title: Long-term clinical performance of short 6-mm implants supporting single crowns in the posterior region: A 10-year cohort study.
    Article Snippet: School of Dentistry, Pontifical Catholic University of Rio Grande do Sul, Porto Alegre, Brazil Private Practice, Porto Alegre, Brazil Private Practice, Jaú, Brazil School of Dentistry, Federal University of Santa Catarina, Florian opolis, Brazil Postgraduate Program in Epidemiology, Federal University of Rio Grande do Sul, Porto Alegre, Brazil School of Dentistry, University of São Paulo, São Paulo, Brazil

    Article Title: Mandibular overdentures retained by 1 or 2 implants: a 5-year randomized clinical trial on implant stability and peri-implant outcomes
    Article Snippet: All participants received 4.1 mm diameter tissue-level implants (Straumann ® Standard Plus – SLActive ® , Institut Straumann AG), installed in the mandible midline (1-IOD; n = 23) or the lateral incisor-canine area bilaterally (2-IOD; n = 24), and loaded after 3 weeks.

    Article Title: Oral rehabilitation and associated quality of life following mandibular reconstruction with free fibula flap: a cross-sectional study
    Article Snippet: Further, the time interval for endosseous implant placement [Straumann SLActive standard or standard plus implants (Straumann GmbH; Freiburg, Germany) or Xive implants (Dentsply Sirona Deutschland GmbH; Bensheim, Germany)], and the duration until consecutive prosthetic restoration were recorded.

    Article Title: Narrow Versus Standard Diameter Implants for Supporting Single Crown Restorations in the Posterior Jaw: A Randomised Controlled Trial
    Article Snippet: Fig. 2 Clinical images of a patient in the standard diameter implant group: (A) surgical guide in situ. (B) osteotomy site with 2.2 mm guiding pin. (C) periapical radiograph of 2.8 mm guiding pin. (D) Straumann Standard Plus Roxolid SLActive RN 4.1 × 10 mm. (E) Dental implant in situ. (F) flap closure with 4-0 PGA resorbable suture. (G) Periapical radiograph immediately after dental implant placement. (H) 3-month post-operative periapical radiograph following placement of healing abutment. (I, J) Delivery of screw-retained implant-supported crown. (K) Peri-apical radiograph immediately after delivery of screw-retained implant-supported crown.

    Article Title: 3D virtual patient-Magnetically retained printed stackable system for implant guided placement: Case report.
    Article Snippet: Correspondence Camila Sales Jreige, Department of Prosthodontics, University of São Paulo School of Dentistry, 2227 Professor Lineu Prestes Avenue, São Paulo, SP, Brazil Email: camilajreige@usp.br Abstract Objective: The aim of this report is to present the complete workflow of 3D virtual patient for planning and performing implant surgery with magnetically retained 3Dprinted stackable guides.. Clinical Considerations: A 3D-printed stackable system was proposed based on bone, dental, and facial references.. Initially, a 66-year-old male patient was digitalized through photographs, cone beam computed tomography, and intraoral scans (Virtuo Vivo, Straumann).

    Significance Assay:

    Article Title: Immediate implant placement and simultaneous bone grafting with bone cement in extraction sockets: A systematic review
    Article Snippet: Implant dimension , 3.3-mm-diameter, 12-mm-long ITI titanium plasma-sprayed Straumann implants , 3-mm-diameter, 10-mm-long B-type cylindrical titanium alloy shape implants , Parallel-wall, screw-type, 3.25-mm-diameter, 11.5- or 13-mm-long titanium implants , Parallel-wall, screw-type, 3.25-mm-diameter, 11.5- or 13-mm-long titanium implants , Standard plus 4.1-mm-diameter, 8-mm-long SLActive (Straumann USA).

    Article Title: Mandibular overdentures retained by 1 or 2 implants: a 5-year randomized clinical trial on implant stability and peri-implant outcomes
    Article Snippet: All participants received 4.1 mm diameter tissue-level implants (Straumann ® Standard Plus – SLActive ® , Institut Straumann AG, Basel, Switzerland), installed according to the manufacturer’s recommendations, using a flapped surgery and early loading protocol.

    Article Title: Evaluation of short dental implant in posterior atrophic partially edentulous maxilla and mandible .
    Article Snippet: Straumann Standard Plus SLActive surface short implant that used in this study characterized by unique implant design where implant body itself has a solid screw parallel-wall configuration, with the thread pitch of 0.8 mm and made of Roxolid (Titanium-Zirconium alloy) with rounded apex, the body has 4.1 mm, and the neck has 4.8mm (for the RN design), the “tulip-shaped” design helps to improve the primary stability at the neck of the implant, especially in the posterior maxilla sites .The polished collar neck provides a crown-toimplant connection at a supra-gingival (Soft Tissue) level, allowing for less crestal bone loss and an excellent peri-implant tissue stability.

    Article Title: Long-term clinical performance of short 6-mm implants supporting single crowns in the posterior region: A 10-year cohort study.
    Article Snippet: School of Dentistry, Pontifical Catholic University of Rio Grande do Sul, Porto Alegre, Brazil Private Practice, Porto Alegre, Brazil Private Practice, Jaú, Brazil School of Dentistry, Federal University of Santa Catarina, Florian opolis, Brazil Postgraduate Program in Epidemiology, Federal University of Rio Grande do Sul, Porto Alegre, Brazil School of Dentistry, University of São Paulo, São Paulo, Brazil

    Article Title: Mandibular overdentures retained by 1 or 2 implants: a 5-year randomized clinical trial on implant stability and peri-implant outcomes
    Article Snippet: All participants received 4.1 mm diameter tissue-level implants (Straumann ® Standard Plus – SLActive ® , Institut Straumann AG), installed in the mandible midline (1-IOD; n = 23) or the lateral incisor-canine area bilaterally (2-IOD; n = 24), and loaded after 3 weeks.

    Article Title: Oral rehabilitation and associated quality of life following mandibular reconstruction with free fibula flap: a cross-sectional study
    Article Snippet: Further, the time interval for endosseous implant placement [Straumann SLActive standard or standard plus implants (Straumann GmbH; Freiburg, Germany) or Xive implants (Dentsply Sirona Deutschland GmbH; Bensheim, Germany)], and the duration until consecutive prosthetic restoration were recorded.

    Article Title: Narrow Versus Standard Diameter Implants for Supporting Single Crown Restorations in the Posterior Jaw: A Randomised Controlled Trial
    Article Snippet: Fig. 2 Clinical images of a patient in the standard diameter implant group: (A) surgical guide in situ. (B) osteotomy site with 2.2 mm guiding pin. (C) periapical radiograph of 2.8 mm guiding pin. (D) Straumann Standard Plus Roxolid SLActive RN 4.1 × 10 mm. (E) Dental implant in situ. (F) flap closure with 4-0 PGA resorbable suture. (G) Periapical radiograph immediately after dental implant placement. (H) 3-month post-operative periapical radiograph following placement of healing abutment. (I, J) Delivery of screw-retained implant-supported crown. (K) Peri-apical radiograph immediately after delivery of screw-retained implant-supported crown.

    Article Title: 3D virtual patient-Magnetically retained printed stackable system for implant guided placement: Case report.
    Article Snippet: Correspondence Camila Sales Jreige, Department of Prosthodontics, University of São Paulo School of Dentistry, 2227 Professor Lineu Prestes Avenue, São Paulo, SP, Brazil Email: camilajreige@usp.br Abstract Objective: The aim of this report is to present the complete workflow of 3D virtual patient for planning and performing implant surgery with magnetically retained 3Dprinted stackable guides.. Clinical Considerations: A 3D-printed stackable system was proposed based on bone, dental, and facial references.. Initially, a 66-year-old male patient was digitalized through photographs, cone beam computed tomography, and intraoral scans (Virtuo Vivo, Straumann).



    Similar Products

    90
    Straumann GmbH tissue-level implants straumann® standard plus – slactive
    Tissue Level Implants Straumann® Standard Plus – Slactive, supplied by Straumann GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/standard+plus+slactive+(straumann)/straumann+tissue+level+implants/pmc11402838-25-5-8
    Average 90 stars, based on 1 article reviews
    tissue-level implants straumann® standard plus – slactive - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    Straumann GmbH tissue level straumann® standard plus slactive
    Studies included in the review
    Tissue Level Straumann® Standard Plus Slactive, supplied by Straumann GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/standard+plus+slactive+(straumann)/straumann+tissue+level+implants/pmc11953539-0-22-24
    Average 90 stars, based on 1 article reviews
    tissue level straumann® standard plus slactive - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    Straumann GmbH titanium– zirconium reduced- diameter implants straumann® standard plus slactive rn, roxolid, diameter
    Studies included in the review
    Titanium– Zirconium Reduced Diameter Implants Straumann® Standard Plus Slactive Rn, Roxolid, Diameter, supplied by Straumann GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/standard+plus+slactive+(straumann)/titanium+zirconium+alloy+narrow+diameter+implants+straumann+roxolid/pm37668109-52-3-5
    Average 90 stars, based on 1 article reviews
    titanium– zirconium reduced- diameter implants straumann® standard plus slactive rn, roxolid, diameter - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    Straumann GmbH implants straumann slactive standard plus rn
    Studies included in the review
    Implants Straumann Slactive Standard Plus Rn, supplied by Straumann GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/standard+plus+slactive+(straumann)/straumann+implant/pm36222311-36-1-2
    Average 90 stars, based on 1 article reviews
    implants straumann slactive standard plus rn - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    Straumann GmbH tissue-level straumann standard plus slactive
    Studies included in the review
    Tissue Level Straumann Standard Plus Slactive, supplied by Straumann GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/standard+plus+slactive+(straumann)/straumann+tissue+level+implants/10__2186_slash_jpr__jpr_d_21_00343-46-2-3
    Average 90 stars, based on 1 article reviews
    tissue-level straumann standard plus slactive - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    Straumann GmbH implant straumann standard plus slactive
    Studies included in the review
    Implant Straumann Standard Plus Slactive, supplied by Straumann GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/standard+plus+slactive+(straumann)/straumann+implant/pmc09292666-82-17-18
    Average 90 stars, based on 1 article reviews
    implant straumann standard plus slactive - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    Straumann GmbH tissue level straumann® standard plus slactive® regular neck implants straumann 033.561s/652s/563s
    Studies included in the review
    Tissue Level Straumann® Standard Plus Slactive® Regular Neck Implants Straumann 033.561s/652s/563s, supplied by Straumann GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/standard+plus+slactive+(straumann)/tissue+level+straumann++standard+plus+slactive++regular+neck+implants+straumann+033+561s+652s+563s/pmc08079530-91-0-2
    Average 90 stars, based on 1 article reviews
    tissue level straumann® standard plus slactive® regular neck implants straumann 033.561s/652s/563s - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    Straumann GmbH tissue level straumann® standard plus slactive® regular neck implants (straumann 033.561s/652s/563s)
    Studies included in the review
    Tissue Level Straumann® Standard Plus Slactive® Regular Neck Implants (Straumann 033.561s/652s/563s), supplied by Straumann GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/standard+plus+slactive+(straumann)/straumann+tissue+level+implants/pm33417279-59-0-9
    Average 90 stars, based on 1 article reviews
    tissue level straumann® standard plus slactive® regular neck implants (straumann 033.561s/652s/563s) - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    Straumann GmbH titanium–zirconium narrow diameter implants straumann® standard plus slactive rn roxolid
    Studies included in the review
    Titanium–Zirconium Narrow Diameter Implants Straumann® Standard Plus Slactive Rn Roxolid, supplied by Straumann GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/standard+plus+slactive+(straumann)/titanium+zirconium+alloy+narrow+diameter+implants+straumann+roxolid/pm32562324-41-3-7
    Average 90 stars, based on 1 article reviews
    titanium–zirconium narrow diameter implants straumann® standard plus slactive rn roxolid - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    Image Search Results


    Studies included in the review

    Journal: Bioinformation

    Article Title: An update on attachment systems for mandibular implant overdentures: A review

    doi: 10.6026/9732063002001623

    Figure Lengend Snippet: Studies included in the review

    Article Snippet: Resende et al. [ ] , 2021 , Randomized Controlled Trial , 1-IOD: 23; 2-IOD: 24 , 2 groups (Single-implant, Double-implant) , Tissue level Straumann® Standard Plus SLActive® , Fully edentulous subjects , 1-IOD group: lower width of keratinized tissue (p = 0.040); 2-IOD group: lower lingual mucosa thickness (p = 0.026) , .

    Techniques: